Vertical Fractional CO2 Laser Machine
How does it works?
Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth, and density that are surrounded by a reservoir of spared epidermal and dermal tissue, allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper laser-delivery systems, enables high-energy treatments while minimizing risks.
Cosmetic Application:
1.Rhytides (Wrinkles)
2.Mottled dyspigmentation
3.Telangiectasia (Red Spots)
4.Solar lentignes (Brown spots)
5.Large pores,Rough skin texture
Medical Application:
1.Actinic keratosis (sun-damaged skin, precancerous lesions)
2.Seborrheic keratosis (sun-damaged skin, precancerous lesions)
3.Sebaceous hyperplasia (yellow, shiny bumps on the face)
4.Rhinophyma (nose swelling and tissue over growth)
5.Epidermal Melasma (Brown spots)
Advantages of System:
1/ RF Laser Tube is more stable than traditional Glass tube, the machine is non serviceable
2/ With the RF laser Tube, the scanning depth can reach the derma layer , to accelerate the collagen re-growth.
3/ RF Laser Tube makes the scanning dot much thinner and less harm
4/ The Laser Tube frequency can reach more than 5000HZ, high scanner can get better treatment effect
5/ Four working modes ,Fractional, CW, Pulse, Ultra Pulse ,one machine can been used in widely in different surgery
6/ Special designed energy self-inspected and energy-replenishment system ,improving the stability and effect
Vaginal Treatment Procedure:
1.Use the digital endoscope to detect the condition of privates.
2.Under the WIZ Scan Mode, insert the WIZ handpiece,Laser irradiation with 360-degree revolution ,irradiating the laser Pulling out the handpiece by checking the scales on guide tip.
3.Under the RF Scan Mode, put the Laser Irradiation on Target area , Rejuvenation and whitening.
Laser source | Metal RF co2 Laser Generator |
Laser Type | 10.6μm |
Output Power | 30W |
Focal length of working head | F=50mm 75mm 100mm |
Indication Beam | Red Diode Laser(650nm, ≤5mW) |
Transmission System | 7-Articulation Joint Spring Arm |
Smoke Exhausting System | Built-in air blow |
Cooling System | Air cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V,50Hz±1Hz |
Dimension | 52*68*3300px |
Weight | 35kg |
Working mode | |
Continuous | Power 1~30W step adjustable each 1 W |
Pulse | Power 1~30W step adjustable each 1 |
Interval time | 1~999ms |
Ultra pulse | Power 1~30W step adjustable each 1
Modulated frequency of 1000 Hz |
Pulse Duration | 90-1000μs |
Scanning mode | |
Scan mode | Ellipse, Rectangular, Triangular, Line, Square,hexagon,round |
Repeat Delay | 0.1s—- 5.0s |
Micro Pulse Energy | 5mJ—50mJ |
Treatment Level | 0.30%—–25.0% |
Passes | 1—–10 times |
Estimated Power | 24mJ–1000J |
Ellipes estimated power | 31mJ—-1000J |
Rectangular estimated power | 24mJ—-981J |
Treatment area | 0.1*0.1mm, —– 15*15mm.(F=50mm) |
Handpiece Velocity | 0.1—–225px2/s |
Scanning Depth | ≤2.0mm |
Vaginal Mode | |
Continuous | 360 degree revolution |
Treatment depth | 100mm |
Treatment head diameter | 30mm |
Max Scanning diameter | 9*9mm2 |
Spot Size Diameter | 0.2-1.0mm |
Focus length | 150mm |
Suggestion parameter setting | 30-40mj/pin |
The Effect:
Find all our constructive solutions to carry out your projects. Know the technical specifications of each product here.